About 19,800 results
Open links in new tab
  1. Rouleaux or cold auto - BloodBankTalk - PathLabTalk

    Feb 27, 2008 · We perform our antibody screens at 37C and IAT only (since AABB STD's says methods that detect SIGNIFICANT antibodies).The problem is, that crossmatches are …

  2. Rouleaux interference - BloodBankTalk - PathLabTalk

    Jan 23, 2020 · Expand It's not uncommon to see rouleaux interference in Gel testing but it's not something we see frequently. The crossmatch question is interesting: Technically, the screen …

  3. saline replacement in serum discrepancy - PathLabTalk

    Nov 12, 2010 · How do you perform saline replacement when there is serum discrepancy due to rouleaux formantion?From the last step,2 drops of saline is added and resuspend it with red …

  4. can you tell if Rouleaux is present just from looking at the gel card ...

    Oct 11, 2009 · I apologize, this may be a stupid question. For example, if you are trying to do a gel cross match and the donor cells have Rouleaux, can you tell that from looking at the gel …

  5. Do you wash your screening cells? For rouleaux? Why?

    Mar 11, 2010 · I had this patient with multiple myeloma. Her antibody screen on gel card had rouleaux reactions for all 3 screening cells. I then washed the screening cells six times with …

  6. Procedure For Making Student Specimens - PathLabTalk

    May 6, 2013 · Does anyone have any procedures that they can share for making up student specimens, either spiking plasma samples with antibodies but even more so, making up …

  7. Is the full crossmatch valid after saline replacement

    Mar 26, 2017 · Hi all, We have a patient with strong rouleaux and an alloantibody. According to our policy, we need to perform a full crossmatch which means the crossmatch is carried from …

  8. anti-A1 or rouleaux? - BloodBankTalk - PathLabTalk

    Feb 26, 2019 · The forward type is an AB patient, your reverse type looks like you have multiple things going on. Because of the negative xm with group O donor red cells and the 1+ reactions …

  9. Rouleaux or cold auto - Page 2 - Transfusion Services - PathLabTalk

    Feb 27, 2008 · My routine for cold/rouleaux encounters is to add two drops of saline and re-spin. With weaker rouleaux reactions, the clumping is ususally dispersed. If not, I incubate the tubes …

  10. Gel card with 1+ reactions showing negative after spinning a …

    Apr 1, 2006 · An ER trauma patient's plasma showed 1+ reactivity in Gel with Screening cell 1 of Immucor's Trio screen. The other two cells were negative. (We buy 3% Immucor screening …